This index covers only the linked sources. Compatibility can depend on exact model, voltage class, communication method, firmware, and manufacturer instructions. An undocumented pairing is Unknown / not documented in these sources; that does not establish incompatibility. This reference is not an installation approval and does not replace the inverter or battery manufacturer’s instructions.
Communication and conditions
Method: CANBus
Cable: No custom cable is required; use a standard RJ45 cable for the outdoor inverter CANBus connection.
- Connect the battery CAN connection to the Sol-Ark Battery CANBus port on the outdoor-rated inverter.
- Enable BMS Lithium Batt and set it to 00.
- Briggs & Stratton’s AmpliPHI Sol-Ark guide names the Sol-Ark 8K; it does not establish a broader model scope here.
Firmware: Sol-Ark Rev. 7 recommends inverter firmware C 1.4.5.2 or later for CANBus communication reliability.
Supporting manufacturer documents
- Low Voltage Battery Integration Guide (opens in a new tab)Sol-Ark · Rev. 7 · Effective March 24, 2026
- Sol-Ark Integration Guide — AmpliPHI 3.8 kWh Batteries (opens in a new tab)Briggs & Stratton Energy Solutions · REV202105181844
- AmpliPHI 3.8 Battery — Product Specifications (opens in a new tab)Briggs & Stratton Energy Solutions · Revision or effective date not stated in source
Communication and conditions
Method: CANBus closed-loop communication
Cable: Sol-Ark Rev. 7 marks a custom cable as required for Fortress; follow its eFlex Max pinout and Fortress cable guidance.
- Enable BMS Lithium Batt and set it to 00 after selecting the documented eFlex Max CAN protocol.
- Fortress says charge and discharge current settings must stay within the inverter rating; its Sol-Ark 12K example caps both at 185A.
- Fortress documents “Sol-Ark 12K” without a submodel suffix, so this entry preserves that stated scope.
Firmware: Sol-Ark Rev. 7 recommends inverter firmware C 1.4.5.2 or later for CANBus communication reliability.
Supporting manufacturer documents
- Low Voltage Battery Integration Guide (opens in a new tab)Sol-Ark · Rev. 7 · Effective March 24, 2026
- eFlex Max Battery-Inverter Integration Guide (opens in a new tab)Fortress Power · Revision or effective date not stated in source
Communication and conditions
Method: CANBus
Cable: Use the 6.6/Sol-Ark crossover cable specified in the Sol-Ark guide.
- Connect the battery controller CAN port through the 6.6/Sol-Ark crossover cable.
- Enable BMS Lithium Batt, set it to 00, and select Activate Battery as directed by Sol-Ark.
- Briggs & Stratton documents a Sol-Ark 15K package with SimpliPHI 6.6 batteries; the exact 15K suffix is not stated in that package article.
Firmware: Sol-Ark Rev. 7 recommends inverter firmware C 1.4.5.2 or later for CANBus communication reliability.
Supporting manufacturer documents
- Low Voltage Battery Integration Guide (opens in a new tab)Sol-Ark · Rev. 7 · Effective March 24, 2026